PE706 Specifications | ||
| Mechanical Specifications and Wiring |
![]() |
![]() |
| Housing :
ABS Encapsulation : epoxy Power/Output Cable: 1/2" model - 2 meters (4 wires), potted all other sizes - M12 x 1 threaded connector cables sold separately, 2 meters (4 wires), straight or right angle Adjustment: 15-turn potentiometer Output Indicator: LED, lit when unit is alarmed |
PE706 1/2" Dimensions
PE706 1" Dimensions PE706 2" Dimensions PE706 4" Dimensions PE706 6" Dimensions PE706 12" Dimensions |
| Mechanical Specifications | Dimensions |
| Electrical Specifications | |||||
| Input Voltage | Supply Ripple | Operating Current maximum |
Leakage Current maximum |
Output Current maximum |
|
| 10-30 VDC | 10% | 20 mA | 2 uA | 100 mA | |
| Sensitivity Adjustment potentiometer |
Sensitivity nominal (ferrous metals) |
Temperature Range |
Relative Humidity |
General Environment |
|
| 15 turns | detect a steel ball 5% of ring diameter in size |
+0o F to +130o F
-20o C to +55o C |
0 - 100% | unaffected
by normal factory conditions of dirt, grease and vibration |
|
| Installation/Setup Procedures | ||
| Mechanical Installation | Electrical Installation | |
|
For 1/2" models, use a 12A272 mounting clamp, or its equivalent, to securely mount the
sensor. All other models have either #10 or 1/4" clearance holes, for mounting to bulkheads or brackets. Units should be mounted as far from metal as possible, and adjusted after they are mounted. As a general rule, sensors mounted side-by-side should be spaced a minimum of half the sensor diameter away from each other, and sensors mounted face-to-face should be spaced three times the sensor diameter away from each other. |
Your sensor's electrical connections must agree with those shown in the corresponding wiring diagram above. | |
| Setup Procedure | ||
|
Apply power. With no target present, turn the adjustment potentiometer fully CW. This is the point of maximum sensitivity. Then, test for detectability. Use actual parts to test detection. Feed your parts through the center of the ring, where sensitivity is the least, to ensure consistency. To reduce sensitivity, turn the potentiometer CCW. Note: PE706 Models are dynamic (AC coupled) devices, which deliver high-sensitivity performance. They do, however, require a 1'/minute (.3 meters/minute) minimum movement of target materials. |
||
![]() |