PE606 Specifications | ||
| Mechanical Specifications and Wiring |
![]() |
![]() |
| Housing :
ABS Encapsulation : epoxy Power/Output Cable: 1/2" model - 2 meters (4 wires), potted all other sizes - M12 x 1 threaded connector cables sold separately, 2 meters (4 wires), straight or right angle Adjustment: 15-turn potentiometer Output Indicator: LED, lit when output is conducting |
PE606 1/2" Dimensions
PE606 1" Dimensions PE606 2" Dimensions PE606 4" Dimensions PE606 6" Dimensions PE606 12" Dimensions |
| Mechanical Specifications | Dimensions |
| Electrical Specifications | |||||
| Input Voltage | Supply Ripple | Operating Current maximum |
Leakage Current maximum |
Output Current maximum |
|
| 10-30 VDC | 10% | 12 mA | 2 uA | 100 mA (NPN)
50 mA (PNP) |
|
| Sensitivity Adjustment potentiometer |
Sensitivity nominal (ferrous metals) |
Temperature Range |
Relative Humidity |
General Environment |
|
| 15 turns | detect a steel ball 15% of ring diameter in size |
+0o F to +130o F
-20o C to +55o C |
0 - 100% | unaffected
by normal factory conditions of dirt, grease and vibration |
|
| Installation/Setup Procedures | ||
| Mechanical Installation | Electrical Installation | |
|
For 1/2" models, use a 12A272 mounting clamp, or its equivalent, to securely mount the
sensor. All other models have either #10 or 1/4" clearance holes, for mounting to bulkheads or brackets. Units should be mounted as far from metal as possible, and adjusted after they are mounted. As a general rule, sensors mounted side-by-side should be spaced a minimum of half the sensor diameter away from each other, and sensors mounted face-to-face should be spaced three times the sensor diameter away from each other. |
Your sensor's electrical connections must agree with those shown in the corresponding wiring diagram above. | |
| Setup Procedure | ||
|
Apply power. With no target present, turn the adjustment potentiometer CW until an alarm condition exists ( Normally Open - LED is lit; Normally Closed - LED is off ). Then, turn the pot CCW until the alarm just resets. This is the point of maximum possible sensitivity; this is not the recommended operating point, however, as temperature fluctuations may cause false alarms or detection failures. For the optimum setting, continue to turn the pot CCW at least 1/4 turn. Note:Use the parts you intend to monitor and test for reliable detection (at the center of the ring, where sensitivity is the least). |
||
![]() |